How does PairGears handle nonconforming parts: rework, replacement or credit?
How does PairGears handle nonconforming parts: rework, replacement or credit?
PairGears first identifies and contains the affected lot, confirms the requirement and evidence, and investigates whether the issue is a manufacturing nonconformance or a service or handling problem. Rework, repair, replacement, return or credit is not automatic: disposition depends on technical feasibility, the approved specification, warranty and order terms, and claim review. Reworked or repaired parts require documented approval and reinspection before release.
Open the claim with a defined requirement and affected lot
Provide the purchase order, part number, drawing revision, lot or batch, quantity, measured results, photos and service conditions. PairGears first checks what requirement applies, whether the reported result is reproducible and which shipped or in-process parts may be affected. Suspect stock should be identified and contained before disposition is chosen.
The PairGears corrective-action evidence FAQ separates immediate containment from permanent corrective action. A complaint description alone is not enough to decide rework, replacement or commercial settlement.

Choose a disposition that preserves the approved requirement
| Disposition | Use only when |
|---|---|
| Rework | The part can be brought fully back to the original approved requirement and then reinspected. |
| Repair or use-as-is | The result may differ from the original requirement and the authorized customer or design authority gives written approval before release. |
| Replacement | A confirmed manufacturing defect and the applicable warranty or order terms support remanufacture or replacement. |
| Return or credit | The commercial resolution is agreed after claim review; PairGears does not publish credit as an automatic remedy. |
| Scrap | The part cannot be safely or economically restored to an approved condition. |
Do not use a concession to bypass a safety, fit, interchangeability or regulatory requirement. The approved disposition should identify who authorized it and which quantity it covers.

Verify the result and close the corrective action separately
Reworked or repaired parts should be reinspected against the applicable acceptance criteria, with the new result linked to the lot and disposition record. For replacement, confirm the revised production and inspection plan before release. For a recurring or material defect, request evidence for containment, verified occurrence and escape causes, permanent action and effectiveness.
PairGears currently publishes a six-month limited warranty for PairGears-made parts, covering confirmed manufacturing defects through repair or replacement after claim review; the purchase order or contract controls the applicable start point and project terms. Misuse, incorrect installation, unauthorized modification and normal wear are listed exclusions. Confirm the terms for the specific order rather than assuming credit or replacement before review.